Main Menu

Publications Highlights View all by category

Types of Publications


Journal Articles

Fu, X. Zhao, Y. Lopez, J.I. Rowan, A. Au, L. Fendler, A. Hazell, S. Xu, H. Horswell, S. Shepherd, S.T. Spencer, C.E. Spain, L. Byrne, F. Stamp, G. O’Brien, T. Nicol, D. Augustine, M. Chandra, A. Rudman, S. Toncheva, A. Furness, A.J. Pickering, L. Kumar, S. Koh, D.-. Messiou, C. Dafydd, D.A. Orton, M.R. Doran, S.J. Larkin, J. Swanton, C. Sahai, E. Litchfield, K. Turajlic, S. Ben Challacombe, Chowdhury, S. Drake, W. Fernando, A. Fotiadis, N. Hatipoglu, E. Harrison-Phipps, K. Hill, P. Horsfield, C. Marafioti, T. Olsburgh, J. Polson, A. Quezada, S. Varia, M. Verma, H. Bates, P.A. (2022). Spatial patterns of tumour growth impact clonal diversification in a computational model and the TRACERx Renal study. Nature ecology & evolution, Vol.6 (1), pp. 88-102.  show abstract

Jensen, M.B. B. Valdetaro, L. Balling, P. Skyt, P.S. Petersen, J.B. Doran, S.J. Sitarz, M.K. Muren, L.P. (2022). Impact of curing conditions on basic dosimetric properties of silicone-based radiochromic dosimeters for photon and proton irradiation. Acta oncologica, Vol.61 (2), pp. 264-268.

Shur, J.D. Doran, S.J. Kumar, S. ap Dafydd, D. Downey, K. O’Connor, J.P. Papanikolaou, N. Messiou, C. Koh, D.-. Orton, M.R. (2021). Radiomics in Oncology: A Practical Guide. Radiographics, Vol.41 (6), pp. 1717-1732.

Doran, S.J. Kumar, S. Orton, M. d’Arcy, J. Kwaks, F. O’Flynn, E. Ahmed, Z. Downey, K. Dowsett, M. Turner, N. Messiou, C. Koh, D.-. (2021). “Real-world” radiomics from multi-vendor MRI: an original retrospective study on the prediction of nodal status and disease survival in breast cancer, as an exemplar to promote discussion of the wider issues. Cancer imaging, Vol.21 (1).  show abstract

McAteer, M.A. O’Connor, J.P. Koh, D.M. Leung, H.Y. Doran, S.J. Jauregui-Osoro, M. Muirhead, N. Brew-Graves, C. Plummer, E.R. Sala, E. Ng, T. Aboagye, E.O. Higgins, G.S. Punwani, S. (2021). Introduction to the National Cancer Imaging Translational Accelerator (NCITA): a UK-wide infrastructure for multicentre clinical translation of cancer imaging biomarkers. British journal of cancer, Vol.125 (11), pp. 1462-1465.  show abstract

Wormald, B.W. Doran, S.J. Ind, T.E. D'Arcy, J. Petts, J. deSouza, N.M. (2020). Radiomic features of cervical cancer on T2-and diffusion-weighted MRI: Prognostic value in low-volume tumors suitable for trachelectomy. Gynecologic oncology, Vol.156 (1), pp. 107-114.

deSouza, N.M. Winfield, J.M. Waterton, J.C. Weller, A. Papoutsaki, M.-. Doran, S.J. Collins, D.J. Fournier, L. Sullivan, D. Chenevert, T. Jackson, A. Boss, M. Trattnig, S. Liu, Y. (2018). Implementing diffusion-weighted MRI for body imaging in prospective multicentre trials: current considerations and future perspectives. European radiology, Vol.28 (3), pp. 1118-1131.

Costa, F. Doran, S.J. Hanson, I.M. Nill, S. Billas, I. Shipley, D. Duane, S. Adamovics, J. Oelfke, U. (2018). Investigating the effect of a magnetic field on dose distributions at phantom-air interfaces using PRESAGE®3D dosimeter and Monte Carlo simulations. Phys med biol, Vol.63 (5), pp. 05NT01-05NT01.  show abstract

Ertas, G. Doran, S.J. Leach, M.O. (2017). A computerized volumetric segmentation method applicable to multi-centre MRI data to support computer-aided breast tissue analysis, density assessment and lesion localization. Medical & biological engineering & computing, Vol.55 (1), pp. 57-68.

Winfield, J.M. Tunariu, N. Rata, M. Miyazaki, K. Jerome, N.P. Germuska, M. Blackledge, M.D. Collins, D.J. de Bono, J.S. Yap, T.A. deSouza, N.M. Doran, S.J. Koh, D.-. Leach, M.O. Messiou, C. Orton, M.R. (2017). Extracranial Soft-Tissue Tumors: Repeatability of Apparent Diffusion Coefficient Estimates from Diffusion-weighted MR Imaging. Radiology, Vol.284 (1), pp. 88-99.  show abstract

Doran, S.J. Hipwell, J.H. Denholm, R. Eiben, B. Busana, M. Hawkes, D.J. Leach, M.O. Silva, I.D. (2017). Breast MRI segmentation for density estimation: Do different methods give the same results and how much do differences matter?. Medical physics, Vol.44 (9), pp. 4573-4592.

O'Flynn, E.A. Blackledge, M. Collins, D. Downey, K. Doran, S. Patel, H. Dumonteil, S. Mok, W. Leach, M.O. Koh, D.-. (2016). Evaluating the diagnostic sensitivity of computed diffusion-weighted MR imaging in the detection of breast cancer. Journal of magnetic resonance imaging, Vol.44 (1), pp. 130-137.

Panek, R. Welsh, L. Dunlop, A. Wong, K.H. Riddell, A.M. Koh, D. Schmidt, M.A. Doran, S. Mcquaid, D. Hopkinson, G. Richardson, C. Nutting, C.M. Bhide, S.A. Harrington, K.J. Robinson, S.P. Newbold, K.L. Leach, M.O. (2016). Repeatability and sensitivity of measurements in patients with head and neck squamous cell carcinoma at 3T. Journal of magnetic resonance imaging, Vol.44 (1), pp. 72-80.

McErlean, C.M. Bräuer-Krisch, E. Adamovics, J. Doran, S.J. (2016). Assessment of optical CT as a future QA tool for synchrotron x-ray microbeam therapy. Physics in medicine and biology, Vol.61 (1), pp. 320-337.

Denholm, R. De Stavola, B. Hipwell, J.H. Doran, S.J. Busana, M.C. Eng, A. Jeffreys, M. Leach, M.O. Hawkes, D. dos Santos Silva, I. (2016). Pre-natal exposures and breast tissue composition: findings from a British pre-birth cohort of young women and a systematic review. Breast cancer research, Vol.18 (1).

McErlean, C.M. Boult, J.K. Collins, D.J. Leach, M.O. Robinson, S.P. Doran, S.J. (2015). Detecting microvascular changes in the mouse spleen using optical computed tomography. Microvascular research, Vol.101, pp. 96-102.

Bräuer-Krisch, E. Adam, J.-. Alagoz, E. Bartzsch, S. Crosbie, J. DeWagter, C. Dipuglia, A. Donzelli, M. Doran, S. Fournier, P. Kalef-Ezra, J. Kock, A. Lerch, M. McErlean, C. Oelfke, U. Olko, P. Petasecca, M. Povoli, M. Rosenfeld, A. Siegbahn, E.A. Sporea, D. Stugu, B. (2015). Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT). Physica medica, Vol.31 (6), pp. 568-583.

Welsh, L. Panek, R. McQuaid, D. Dunlop, A. Schmidt, M. Riddell, A. Koh, D.-. Doran, S. Murray, I. Du, Y. Chua, S. Hansen, V. Wong, K.H. Dean, J. Gulliford, S. Bhide, S. Leach, M.O. Nutting, C. Harrington, K. Newbold, K. (2015). Prospective, longitudinal, multi-modal functional imaging for radical chemo-IMRT treatment of locally advanced head and neck cancer: the INSIGHT study. Radiation oncology, Vol.10 (1).

Doran, S. Gorjiara, T. Kacperek, A. Adamovics, J. Kuncic, Z. Baldock, C. (2015). Issues involved in the quantitative 3D imaging of proton doses using optical CT and chemical dosimeters. Phys med biol, Vol.60 (2), pp. 709-726.  show abstract

Palmer, A.L. Di Pietro, P. Alobaidli, S. Issa, F. Doran, S. Bradley, D. Nisbet, A. (2013). Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE[sup [registered sign]] radiochromic plastic. Med. phys., Vol.40 (6), pp. 061707-11.

Shin, H.-. Orton, M.R. Collins, D.J. Doran, S.J. Leach, M.O. (2013). Stacked autoencoders for unsupervised feature learning and multiple organ detection in a pilot study using 4D patient data. Ieee trans pattern anal mach intell, Vol.35 (8), pp. 1930-1943.  show abstract

Doran, S.J. Abdul Rahman, A.T. Bräuer-Krisch, E. Brochard, T. Adamovics, J. Nisbet, A. Bradley, D. (2013). Establishing the suitability of quantitative optical CT microscopy of PRESAGE® radiochromic dosimeters for the verification of synchrotron microbeam therapy. Phys med biol, Vol.58 (18), pp. 6279-6297.  show abstract

Doran, S.J. Yatigammana, D.N. (2012). Eliminating the need for refractive index matching in optical CT scanners for radiotherapy dosimetry: I Concept and simulations. Phys med biol, Vol.57 (3), pp. 665-683.  show abstract

Doran, S.J. d'Arcy, J. Collins, D.J. Andriantsimiavona, R. Orton, M. Koh, D.-. Leach, M.O. (2012). Informatics in radiology: development of a research PACS for analysis of functional imaging data in clinical research and clinical trials. Radiographics, Vol.32 (7), pp. 2135-2150.  show abstract

Gorjiara, T. Kuncic, Z. Doran, S. Adamovics, J. Baldock, C. (2012). Water and tissue equivalence of a new PRESAGE (R) formulation for 3D proton beam dosimetry: A Monte Carlo study. Medical physics, Vol.39 (11), pp. 7071-7079.

Alqathami, M. Blencowe, A. Yeo, U.J. Doran, S.J. Qiao, G. Geso, M. (2012). Novel multicompartment 3-dimensional radiochromic radiation dosimeters for nanoparticle-enhanced radiation therapy dosimetry. Int j radiat oncol biol phys, Vol.84 (4), pp. e549-e555.  show abstract

Abdul Rahman, A.T. Bräuer-Krisch, E. Brochard, T. Adamovics, J. Clowes, S.K. Bradley, D. Doran, S.J. (2011). Sophisticated test objects for the quality assurance of optical computed tomography scanners. Phys med biol, Vol.56 (14), pp. 4177-4199.  show abstract

Ertas, G. Doran, S. Leach, M.O. (2011). Computerized detection of breast lesions in multi-centre and multi-instrument DCE-MR data using 3D principal component maps and template matching. Phys med biol, Vol.56 (24), pp. 7795-7811.  show abstract

Doran, S.J. (2010). Imaging and 3-D dosimetry: top tips for MRI and optical CT. Journal of physics: conference series, Vol.250, pp. 012086-012086.

Nowais, S.A. Kacperek, A. Brunt, J.N. Adamovics, J. Nisbet, A. Doran, S.J. (2010). An investigation of the response of the radiochromic dosimeter PRESAGETMto irradiation by 62 MeV protons. Journal of physics: conference series, Vol.250, pp. 012034-012034.

Doran, S. Thomas, R. Hollingdale, R. Adamovics, J. Nisbet, A. (2010). Electron dosimetry in the presence of small cavities. Journal of physics: conference series, Vol.250, pp. 012090-012090.

Rahman, A.T. Bräuer-Krisch, E. Brochard, T. Adamovics, J. Bradley, D. Doran, S. (2010). Verification of synchrotron microbeam radiation therapy using a purpose-built optical CT microscope. Journal of physics: conference series, Vol.250, pp. 012083-012083.

Baldock, C. De Deene, Y. Doran, S. Ibbott, G. Jirasek, A. Lepage, M. McAuley, K.B. Oldham, M. Schreiner, L.J. (2010). Polymer gel dosimetry. Physics in medicine and biology, Vol.55 (5), pp. R1-63.

Doran, S.J. Brochard, T. Adamovics, J. Krstajic, N. Bräuer-Krisch, E. (2010). An investigation of the potential of optical computed tomography for imaging of synchrotron-generated x-rays at high spatial resolution. Phys med biol, Vol.55 (5), pp. 1531-1547.  show abstract

Ibrahim, H. Petrou, M. Wells, K. Doran, S. Olsen, Ø. (2010). Automatic Volumetric Liver Segmentation from MRI Data. International journal of computer theory and engineering, , pp. 176-179.

Doran, S.J. Stanley, S.J. Jenneson, P.M. Prott, E. Adamovics, J. (2009). RadBall: A new departure for 3-D dosimetry. Journal of physics: conference series, Vol.164, pp. 012042-012042.

Krstajić, N. Doran, S. (2009). Initial characterization of fast laser scanning optical CT apparatus for 3-D dosimetry. Journal of physics: conference series, Vol.164, pp. 012022-012022.

Doran, S.J. (2009). The history and principles of optical computed tomography for scanning 3-D radiation dosimeters: 2008 update. Journal of physics: conference series, Vol.164, pp. 012020-012020.

Al-Nowais, S. Doran, S.J. (2009). CCD-based optical CT scanning of highly attenuating phantoms. Journal of physics: conference series, Vol.164, pp. 012023-012023.

Al-Nowais, S. Nisbet, A. Adamovics, J. Doran, S.J. (2009). An attempt to determine the saturation dose for PRESAGE. Journal of physics: conference series, Vol.164, pp. 012043-012043.

Wai, P. Adamovics, J. Krstajic, N. Ismail, A. Nisbet, A. Doran, S. (2009). Dosimetry of the microSelectron-HDR Ir-192 source using PRESAGE and optical CT. Appl radiat isot, Vol.67 (3), pp. 419-422.  show abstract

Al-Nowais, S. Doran, S. Kacperek, A. Krstajic, N. Adamovics, J. Bradley, D. (2009). A preliminary analysis of LET effects in the dosimetry of proton beams using PRESAGE and optical CT. Appl radiat isot, Vol.67 (3), pp. 415-418.  show abstract

Doran, S.J. (2009). The history and principles of chemical dosimetry for 3-D radiation fields: gels, polymers and plastics. Appl radiat isot, Vol.67 (3), pp. 393-398.  show abstract

Krstajić, N. Doran, S.J. (2007). Fast laser scanning optical-CT apparatus for 3D radiation dosimetry. Phys med biol, Vol.52 (11), pp. N257-N263.  show abstract

Krstajić, N. Doran, S.J. (2007). Characterization of a parallel-beam CCD optical-CT apparatus for 3D radiation dosimetry. Phys med biol, Vol.52 (13), pp. 3693-3713.  show abstract

Krstajić, N. Doran, S.J. (2006). Characterization of a parallel beam CCD optical-CT apparatus for 3D radiation dosimetry. Journal of physics: conference series, Vol.56, pp. 195-198.

Krstajić, N. Doran, S.J. (2006). Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry. Phys med biol, Vol.51 (8), pp. 2055-2075.  show abstract

Doran, S.J. Bourgeois, M.E. Leach, M.O. (2005). Burst imaging - Can it ever be useful in the clinic?. Concepts in magnetic resonance part a, Vol.26A (1), pp. 11-24.

Doran, S.J. Charles-Edwards, L. Reinsberg, S.A. Leach, M.O. (2005). A complete distortion correction for MR images: I Gradient warp correction. Physics in medicine and biology, Vol.50 (7), pp. 1343-19.

Reinsberg, S.A. Doran, S.J. Charles-Edwards, E.M. Leach, M.O. (2005). A complete distortion correction for MR images: II Rectification of static-field inhomogeneities by similarity-based profile mapping. Phys med biol, Vol.50 (11), pp. 2651-2661.  show abstract

Wycherley, J. Doran, S. Beebee, T.J. (2003). Tracing aliens: Identification of introduced water frogs in Britain by male advertisement call characteristics. Herpetological journal, Vol.13 (1), pp. 43-8.

Wycherley, J. Doran, S. Beebee, T.J. (2002). Frog calls echo microsatellite phylogeography in the European pool frog (Rana lessonae). Journal of zoology, Vol.258, pp. 479-6.

Wycherley, J. Doran, S. Beebee, T.J. (2002). Male advertisement call characters as phylogeographical indicators in European water frogs. Biological journal of the linnean society, Vol.77 (3), pp. 355-11.

Dzik-Jurasz, A. Domenig, C. George, M. Wolber, J. Padhani, A. Brown, G. Doran, S. (2002). Diffusion MRI for prediction of response of rectal cancer to chemoradiation. Lancet, Vol.360 (9329), pp. 307-2.

Doran, S.J. Koerkamp, K.K. Bero, M.A. Jenneson, P. Morton, E.J. Gilboy, W.B. (2001). A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results. Phys med biol, Vol.46 (12), pp. 3191-3213.  show abstract

Wycherley, J. Beebee, T. Doran, S. (2001). Regional accents in the Pool Frog? Development of new computer analytical techniques aids bioacoustic separation of Pool Frog populations and may elucidate the status of Norfolk Pool Frogs. Mitteilungen aus dem museum für naturkunde in berlin. zoologische reihe, Vol.77 (1), pp. 25-30.

Wheeler-Kingshott, C.A. Thomas, D.L. Lythgoe, M.F. Guilfoyle, D. Williams, S.R. Doran, S.J. (2000). Burst excitation for quantitative diffusion imaging with multiple b-values. Magnetic resonance in medicine, Vol.44 (5), pp. 737-9.

Wheeler-Kingshott, C.A. Crémillieux, Y. Doran, S.J. (2000). Burst imaging: rotation artifacts and how to correct them. J magn reson, Vol.143 (1), pp. 161-171.  show abstract

McJury, M. Oldham, M. Cosgrove, V.P. Murphy, P.S. Doran, S. Leach, M.O. Webb, S. (2000). Radiation dosimetry using polymer gels: methods and applications. Br j radiol, Vol.73 (873), pp. 919-929.  show abstract

Hepworth, S.J. Leach, M.O. Doran, S.J. (1999). Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (II) modelling oxygen diffusion. Physics in medicine and biology, Vol.44 (8), pp. 1875-10.

Wolber, J. Doran, S.J. Leach, M.O. Bifone, A. (1998). Measuring diffusion of xenon in solution with hyperpolarized Xe-129 NMR. Chemical physics letters, Vol.296 (3-4), pp. 391-6.

Cremillieux, Y. WheelerKingshott, C.A. Briguet, A. Doran, S.J. (1997). STEAM-Burst: A single-shot, multi-slice imaging sequence without rapid gradient switching. Magnetic resonance in medicine, Vol.38 (4), pp. 645-8.

Doran, S.J. Jakob, P. Decorps, M. (1996). Rapid repetition of the ''Burst'' sequence: The role of diffusion and consequences for imaging. Magnetic resonance in medicine, Vol.35 (4), pp. 547-7.

JAKOB, P.M. ZIEGLER, A. DORAN, S.J. DECORPS, M. (1995). ECHO-TIME-ENCODED BURST IMAGING (EBI) - A NOVEL TECHNIQUE FOR SPECTROSCOPIC IMAGING. Magnetic resonance in medicine, Vol.33 (4), pp. 573-6.

Doran, S.J. Décorps, M. (1995). A Robust, Single-Shot Method for Measuring Diffusion Coefficients Using the “Burst” Sequence. Journal of magnetic resonance, series a, Vol.117 (2), pp. 311-316.

PEARCE, R.B. SUMER, S. DORAN, S.J. CARPENTER, T.A. HALL, L.D. (1994). NONINVASIVE IMAGING OF FUNGAL COLONIZATION AND HOST RESPONSE IN THE LIVING SAPWOOD OF SYCAMORE (ACER-PSEUDOPLATANUS L) USING NUCLEAR-MAGNETIC-RESONANCE. Physiological and molecular plant pathology, Vol.45 (5), pp. 359-26.

Doran, S.J. Carpenter, T.A. Hall, L.D. (1994). Noninvasive measurement of temperature distributions with high spatial resolution using quantitative imaging of NMR relaxation times. Review of scientific instruments, Vol.65 (7), pp. 2231-2237.

MACKENZIE, R. SHAH, N.J. DORAN, S. DIXON, A.K. (1993). TECHNICAL NOTE - A MULTIPURPOSE RULER FOR MAGNETIC-RESONANCE-IMAGING. British journal of radiology, Vol.66 (786), pp. 545-3.

Doran, S.J. Attard, J.J. Roberts, T.P. Adrian Carpenter, T. Hall, L.D. (1992). Consideration of random errors in the quantitative imaging of NMR relaxation. Journal of magnetic resonance (1969), Vol.100 (1), pp. 101-122.

Denholm, R. De Stavola, B. Hipwell, J. Doran, S.J. Busana, M. Jeffreys, M. Leach, M.O. Hawkes, D. dos-Santos-Silva, I. Growth trajectories, breast size, and breast-tissue composition in a British pre-birth cohort of young women. American journal of epidemiology, .

Doran, S. Leach, M.O. Circulating growth and sex hormone levels and breast-tissue composition in young nulliparous women. Cancer epidemiology, biomarkers and prevention, .

Costa, F. Doran, S.J. Hanson, I.M. Adamovics, J. Nill, S. Oelfke, U. Edge effects in 3D dosimetry: characterisation and correction of the non-uniform dose response of PRESAGE®. Physics in medicine & biology, Vol.65 (9), pp. 095003-095003.

Fu, X. Zhao, Y. Lopez, J. Rowan, A. Au, L. Fendler, A. Hazell, S. Xu, H. Horswell, S. Shepherd, S. Spain, L. Byrne, F. Stamp, G. O'Brien, T. Nicol, D. Augustine, M. Chandra, A. Rudman, S. Toncheva, A. Furness, A. Pickering, L. Orton, M. Doran, S. Koh, D.-. Messiou, C. Dafydd, D.A. Kumar, S. Larkin, J. Swanton, C. Sahai, E. Litchfield, K. Turajlic, S. Bates, P. Spatial patterns of tumour growth impact clonal diversification: computational modelling and evidence in the TRACERx Renal study. , .  show abstract

Doran, S.J. Al Sa’d, M. Petts, J.A. Darcy, J. Alpert, K. Cho, W. Sanchez, L.E. Alle, S. El Harouni, A. Genereaux, B. Ziegler, E. Harris, G.J. Aboagye, E.O. Sala, E. Koh, D.-. Marcus, D. Integrating the OHIF Viewer into XNAT: Achievements, Challenges and Prospects for Quantitative Imaging Studies. Tomography, Vol.8 (1), pp. 497-512.  show abstract


Book Chapters

Doran, S. Leach, M.O. (2012). Webb's Physics of Medical Imaging. In Webb, S.Flower, M.A. (Eds.), Webb's Physics of Medical Imaging. 2nd ed. (p. 811). CRC Press, ISBN: 9780750305730.

Doran, S.J. (1996). Chapter 21 Quantitative magnetic resonance imaging: applications and estimation of errors. Data Handling in Science and Technology. (pp. 452-488). Elsevier.


Conferences

Doran, S.J. (2019). Radiotherapy in the presence of magnetic fields: a brief review of detector response characteristics and the contribution of 3-D measurements to the study of dose distributions at interfaces, Journal of Physics: Conference Series, Vol.1305 (1), p.012006.

Costa, F.Menten, M.J.Doran, S.Adamovics, J.Hanson, I.M.Nill, S.Oelfke, U. (2019). Dose verification of dynamic MLC-tracked radiotherapy using small PRESAGE® 3D dosimeters and a motion phantom, Journal of Physics: Conference Series, Vol.1305 (1), p.012068.

Costa, F.Doran, S.Adamovics, J.Nill, S.Hanson, I.M.Oelfke, U. (2019). Characterization of small PRESAGE® samples for measurements near the dosimeter edges, Journal of Physics: Conference Series, Vol.1305 (1), p.012009.

Costa, F.Doran, S.Nill, S.Duane, S.Shipley, D.Billas, I.Adamovics, J.Oelfke, U. (2017). Development of a methodology to study the effect of magnetic field on dose distributions in an MR-linac, using PRESAGE® and Monte Carlo calculations, Journal of Physics: Conference Series, Vol.847, p.012058.

McErlean, C.Bräuer-Krisch, E.Adamovics, J.Leach, M.O.Doran, S.J. (2015). High resolution 3D dosimetry for microbeam radiation therapy using optical CT, Journal of Physics: Conference Series, Vol.573, p.012032.

Doran, S.J.Gorjiara, T.Adamovics, J.Kuncic, Z.Kacperek, A.Baldock, C. (2015). The quenching effect in PRESAGE® dosimetry of proton beams: Is an empirical correction feasible?, Journal of Physics: Conference Series, Vol.573, p.012043.

Costa, M.McErlean, C.Rivens, I.Adamovics, J.Leach, M.O.ter Haar, G.Doran, S.J.IOP, (2015). PRESAGE (R) as a new calibration method for high intensity focused ultrasound therapy, 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), Vol.573.

Gorjiara, T.Kacperek, A.Kuncic, Z.Baldock, C.Doran, S. (2013). Preliminary characterization of PRESAGE®for 3D dosimetry of 62 MeV proton beam, Journal of Physics: Conference Series, Vol.444, p.012058.

Alqathami, M.Blencowe, A.Yeo, U.J.Franich, R.Doran, S.Qiao, G.Geso, M. (2013). Enhancement of radiation effects by bismuth oxide nanoparticles for kilovoltage x-ray beams: A dosimetric study using a novel multi-compartment 3D radiochromic dosimeter, Journal of Physics: Conference Series, Vol.444, p.012025.

Doran, S.J.Rahman, A.T.Braeuer-Krisch, E.Brochard, T.Adamovics, J.IOP, (2013). Ultra-high resolution optical CT dosimetry for the visualisation of synchrotron microbeam therapy doses, 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), Vol.444.

Doran, S.J.IOP, (2013). How to perform an optical CT scan: an illustrated guide, 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), Vol.444.

Shin, H.-.Orton, M.Collins, D.J.Doran, S.Leach, M.O. (2011). Autoencoder in Time-Series Analysis for Unsupervised Tissues Characterisation in a Large Unlabelled Medical Image Dataset, Presented at 2011 Tenth International Conference on Machine Learning and Applications (ICMLA), 2011 10th International Conference on Machine Learning and Applications and Workshops, .

Reed, S.Ertas, G.Doran, S.Warren, R.M.Leach, M.O. (2010). Robustness of interactive intensity thresholding based breast density assessment in MR-Mammography, Presented at Conference on Medical Imaging 2010 - Computer-Aided Diagnosis, San Diego, CA. MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, Vol.7624, p. 5.

Rahman, A.T.Bradley, D.A.Doran, S.J.Thierry, B.Braeuer-Krisch, E.Bravin, A. (2010). The thermoluminescence response of Ge-doped silica fibres for synchrotron microbeam radiation therapy dosimetry, Presented at 11th International Symposium on Radiation Physics, Melbourne, AUSTRALIA. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, Vol.619 (1-3), pp.167-4.

Wai, P.Bedford, J.Doran, S.Warrington, A. (2009). TRUE 3D DOSIMETRY OF SINGLE ARC VOLUMETRIC MODULATED ARC THERAPY (VMAT) FOR THE TREATMENT OF PROSTATE, Radiotherapy and Oncology, Vol.92, pp.S218-S219.

Hollingdale, R.Doran, S.Nisbet, A. (2008). AN INVESTIGATION OF THE DOSE DISTRIBUTION IN THE 3D DOSIMETER PRESAGETM WITH ELECTRON RADIATION., RADIOTHERAPY AND ONCOLOGY, Vol.88, p.S381.

Krstajic, N.Doran, S.J. (2005). Parallel beam optical tomography apparatus for 3-d radiation dosimetry, Presented at Opto-Ireland 2005 Conference, Dublin, IRELAND. Opto-Ireland 2005: Imaging and Vision, Vol.5823, pp.175-8.

Ibrahim, H.Petrou, M.Wells, K.Doran, S.Olsen, O. (2004). Preprocessing for use in automatic volumetric liver segmentation from NMR data, Presented at Nuclear Science Symposium/Medical Imaging Conference, Rome, ITALY. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, , pp.2783-5.

Jenneson, P.M.Bero, M.A.Gilboy, W.B.Doran, S.J.Morton, E.J. (1999). Three-dimensional optical tomography of dose distribution using radiation sensitive transparent gels, Presented at 1999 IEEE Nuclear Science Symposium and Medical Imaging Conference, SEATTLE, WA. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, , pp.538-3.

Styrkas, D.Doran, S.J.Gilchrist, T.Keddie, J.L.Lu, J.R.Murphy, E.Sackin, R.Su, T.J.Tzitzinou, A. (1999). Application of ellipsometry to polymers at interfaces and in thin films, Presented at Conference on Polymer Surfaces and Interfaces III, DURHAM UNIV, DURHAM, ENGLAND. POLYMER SURFACES AND INTERFACES III, , pp.1-42.

Hepworth, S.J.McJury, M.Oldham, M.Morton, E.J.Doran, S.J. (1999). Dose mapping of inhomogeneities positioned in radiosensitive polymer gels, Presented at 9th Symposium on Radiation Measurements and Applications, ANN ARBOR, MICHIGAN. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, Vol.422 (1-3), pp.756-5.

In this section

Publications